Tuning hot-end temperature controller

From re:3D
Revision as of 19:57, 26 March 2016 by Matthew (Talk | contribs)

Jump to: navigation, search

Single Extruder

  1. Connect Gigabot's power and USB cables.
  2. Use Pronterface connect to Gigabot.
  3. Turn on the head fan by typing M106 S255 command in the lower right corner of Pronterface.
  4. If you have previously been printing wait for the hot-end to cool below 100C.
  5. In Pronterface type into the data entry box at the lower right corner:
For GB2 use “M303 S200”
For GB3 Left Extruder use “M303 E0 S200”

This will start the PID auto-tune function in the Marlin Firmware. The hot-end will cycle the heat up and down for a couple minutes until displaying the message: "PID Autotune Complete". Write down the last set of output values given.

Classic PID
Kp: 50.03
Ki: 1.98
Kd: 150.98

Adjusting the firmware

  1. In Pronterface DISCONNECT from Gigabot, Close Pronterface, RESTART Pronterface.
  2. Connect to Gigabot.
  3. In Pronterface type into the data entry box at the lower right corner: "M301 H1 P(your Kp value) I(your Ki value) D(your Kd value)".
  4. It should look like this using the example above:

"M301 H1 P50.03 I1.98 D150.98" This will temporarily change the current settings for the temperature controller

  1. It should look like this using the example above: "M301 H1 P50.03 I1.98 D150.98" This will TEMPORARILY change the current settings for the temperature controller.
  2. In Pronterface type into the data entry box at the lower right corner: "M500" This will make changes permanent.
  3. In Pronterface: Set hot-end temperature to 200C and watch that it comes up to temp, overshoot the target temp slightly, undershoot temp slightly and then settles onto the target temp within 1-2 deg.

Dual Extruder

  1. Connect Gigabot's power and USB cables.
  2. In Pronterface connect to Gigabot.
  3. Turn on the head fan by typing M106 S255 command in the lower right corner of Pronterface.
  4. If you have previously been printing wait for the hot-end to cool.
  5. In Pronterface type into the data entry box at the lower right corner:
For GB3 Left Extruder use “M303 E0 S200”
For GB3 Right Extruder use “M303 E1 S200”

This will start the PID auto-tune function in the Marlin Firmware. The hot-end will cycle the heat up and down for a couple minutes until displaying the message: "PID Autotune Complete". Write down the last set of output values given.

Classic PID
Kp: 50.03
Ki: 1.98
Kd: 150.98

Adjusting the firmware

  1. In Pronterface disconnect from Gigabot, Close Pronterface, Restart Pronterface.
  2. Connect to Gigabot.
  3. In Pronterface type into the data entry box at the lower right corner:

Left Extruder "M301 H1 P(your Kp value) I(your Ki value) D(your Kd value)" Right Extruder "M301 H2 P(your Kp value) I(your Ki value) D(your Kd value)"

  1. It should look like this using the example above: "M301 H1 P50.03 I1.98 D150.98" This will TEMPORARILY change the current settings for the temperature controller.
  2. In Pronterface type into the data entry box at the lower right corner: "M500" This will make changes permanent.
  3. In Pronterface: Set hot-end temperature to 200C and watch that it comes up to temp, overshoot the target temp slightly, undershoot temp slightly and then settles onto the target temp within 1-2 deg.